The Huron is more than a data-acquisition and control system. This fully functional instrumentation system on a board has the following features:
Analog Inputs
8 differential and 6 single-ended input channels
± 4 mV to ± 4 V in programmable decade gain ranges
High-current built-in bridge supply, for 2, 3 or 4-wire connections
Processing of acquired data into your choice of units
Built-in data processing for the following sensors:
 |
J and K-type thermocouples
|
 |
RTDs (100W and 1 kW Platinum)
|
 |
Bridge-based pressure and force sensors
|
 |
Magnetic-vane or switch-closure flow sensors
|
 |
ADI AD22100 silicon temperature sensors
|
Processing library routines downloadable for other sensors
Simple one or two-point calibration
Calibration parameters downloadable through serial port
Built-in milliohmmeter
12-bit converter resolution
Digital I/O
16 input and 16 output bit-lines with serial bus extension; 8 of each on-board
2 flow sensor inputs count to 200 Hz
Frequency counter input measures to 500 kHz with 16-bit resolution
2 programmable pulse-width, single-shot outputs
2 PCM outputs directly drive PCM servomotors
SPDT, 3 A relay output
Channel-Scanning Schedules
Total scan rates of all channels: 200 Hz
Regular sampling intervals for all channels at programmable rates
Data Recorder & Telemetry
Records telemetered channels. Plays back frames of time-stamped and processed data
ERASE, RECORD on/off, and PLAYBACK functions work like tape recorder
Recording time to full memory and percentage of memory left commands
32 kbytes of recorder memory for capturing transient events, capture 16,384 channel samples
Telemetry sends database of selected channels
over serial port while turned on
Clock
Real-time clock sets and runs with 0.1 second resolution
User Interface
Reliable IMPEL operating-system/language interprets from a list of user commands
Libraries of transducer types and application programs compile to extend functional capability
Power and software fault restart options for reliable recovery and operation
Network up to 8 Hurons with RS-485 option
RS-232 or RS-485 serial-port options
System Features
Standard computer supply: 5 V, ± 12 V, or 5 V with on-board ± 12 V converter option.
Compact board: 7.15 ´ 4.15 inches.
Optional plastic enclosure.
User and technical reference manuals.
Accessories:
PG2 dual pulse amplifier, PS1 battery converter, FP3 front-panel interface
Applications
 |
Remote data acquisition, processing and control
|
 |
Automated machine control
|
 |
Semi-custom OEM controllers
|
 |
Vehicle monitoring subsystem
|
 |
Test-stand instrumentation
|
 |
Sounding rocket flight controller
|